Industrial Network Installation and PLC Integration
We examine PLC, remote I/O and drive communication on production lines. We plan how machine data will be transferred to SCADA, MES and ERP, and we assess control traffic and data transfer separately.
Siemens S7 / ET200SPPROFINETOPC UAMQTT
OT network architecture
Topology, redundancy, IP/VLAN plan
PLC data integration
Controlling PLC read load and cycle time
Production visibility
Line status, downtime and production tracking
Segmentation and security
Network zones and permitted connections
Industrial networking and data integration services
Below you will find, one by one, the work needed to renew a production line’s network, track down intermittent communication dropouts or bring machine data into corporate systems.
Industrial Ethernet and Factory Networks
We map switches, cables and connected devices from machine cabinets to the plant backbone.
PROFINET and PROFIBUS Communication
We investigate intermittent dropouts between PLCs, remote I/O and drives using device diagnostic logs, port counters and the field topology.
PLC–PLC and PLC–Server Integration
We carry line status and coordination information between PLCs, and monitoring and reporting data between PLCs and servers.
OPC UA, MQTT and Data Integration
We read the data model a machine exposes via OPC UA and, in projects that need MQTT, distribute this data to applications through a broker.
SCADA, MES and ERP Connectivity
We identify which system production orders come from and where production quantity and scrap data are generated.
IIoT and Production Data Collection
We determine the signals and sampling rates needed for production, quality, energy or maintenance.
OT Cyber Security and Segmentation
We inventory the cells, engineering workstations and external maintenance connections in the production network.
Industrial Network Monitoring and Fault Analysis
For intermittent communication dropouts, we compare PLC and HMI logs, switch counters and downtime records on a single timeline.
Edge Gateways and Protocol Conversion
To collect data from machines that use different protocols, we review the existing interfaces, manufacturer support and open data maps.
IT/OT Integration Consulting
In a new machine, MES or energy monitoring project, we define who owns the network, the data and the access rules.
Production Monitoring and Dashboards
We show line status on operator screens, recurring stoppages on maintenance screens, and shift and OEE indicators on management screens.
Industrial Wireless and Mobile Terminals
In warehouse and production areas, we test handheld terminals, forklift displays and mobile equipment along the routes where they are used.
Factory OT Infrastructure Discovery
Before any investment, we record on site which PLCs, switches, protocols and data flows are in use.
If you are not sure which service to start with, start with a survey
In a short call, we work out together whether the problem lies in the network, the data, security or the organisation.
How does machine data reach MES and ERP?
PLCs and field devices handle the machine’s control communication. We collect the data needed for monitoring through the existing SCADA, an OPC UA server or a gateway suited to the site. Depending on the project’s needs, the data is transferred to a historian, MES or ERP. We show control connections and corporate data flows separately in the diagram.
OPC UA is a protocol and interface through which a PLC or SCADA exposes data. A gateway is a device or software component that reads and converts different protocols. In projects that use MQTT, the gateway or collection software publishes the data to a broker; applications receive the data by subscribing to the broker.
Not every project requires all of these components. Whether an OT DMZ is needed, and where it is placed, depends on the plant’s network structure and access requirements. Product names are examples and do not imply a manufacturer partnership.
Survey first, then change
For every change on a live production network, we write down the test steps, configuration backup and rollback path in advance. We apply the change at a time approved by the plant.
Discovery and inventory
We build an inventory of PLCs, switches, gateways, protocols and connections from existing records and an on-site review. If a new measurement point is needed, we assess its impact with the plant team.
Segmentation and design
Topology, IP plan, access paths and security boundaries; measurable acceptance criteria.
Controlled implementation
Test window, configuration backup, rollback plan and change record.
Monitoring and improvement
Documentation, alarms, performance tracking and sustainable maintenance.
Automation field and IT infrastructure at the same table
After establishing communication, we also hand over the monitoring settings, configuration backups and maintenance documentation. We apply our experience in corporate networking, systems and security together with the priorities of the production floor.
We look for answers to three clear questions
Where does it break?
In the PLC, network, gateway, application or data consumption layer?
How critical is it?
How large are the risks of production downtime, data loss and access?
What is the goal?
Stable communication, data visibility or corporate integration?
Example project scenarios
The following are typical project scenarios; they are not completed customer references.
Renewing the network of an existing line
We identify unmanaged switches, unlabelled connections and common points of failure. We split the renewal into phases according to the line’s operating schedule.
Bringing PLC data to a server
To transfer production, downtime, energy and process data to a server, we first define the signals to be read and how often. We measure the read load on a pilot connection and proceed with suitable settings.
Production outage analysis
We distinguish intermittent dropouts, packet loss, loops and configuration problems from one another using the alarm timeline, port counters and traffic captures.
Secure remote maintenance access
In plants where machine manufacturers connect via modems and permanent VPNs, moving to single-point, authenticated, time-limited and logged access.
Multi-vendor equipment integration
Bringing machines from different manufacturers and generations into a common data layer with edge gateways and a standard data model.
Live production dashboards
We show line status for operators, downtime and fault information for maintenance, and shift and OEE indicators for production management. For each indicator, we state its source and last update time.
The factory floor and corporate infrastructure are handled together
Corporate LAN/WAN and campus networks
network.eretek.com handles the office network that the production network connects to, the campus backbone, WAN and corporate wireless network projects.
Go to the Network site ↗
OT/ICS security assessment
siberguvenlik.eretek.com provides risk assessment, security testing and security monitoring services for OT environments.
Go to the OT security service ↗
Servers, virtualization and backup
sistem.eretek.com builds and manages the virtualization, backup and disaster recovery infrastructure that historian, SCADA and MES servers run on.
Go to the Systems site ↗
Most frequently asked before a proposal
Is PROFINET the same as regular Ethernet?
No. PROFINET is a protocol that runs on Ethernet infrastructure and is designed for the real-time communication needs of industrial automation. Not every Ethernet switch or topology is suitable for every PROFINET application; RT, IRT or TSN support is verified separately for each device.
Can every PLC send data directly to a Linux server?
The same method does not apply to every PLC and firmware. Supported protocols, access licences, network permissions and data requirements are checked, and OPC UA, Modbus TCP, suitable S7 access or a gateway is chosen accordingly.
Should we connect the PLC directly to the ERP?
In most scenarios, a manageable data integration layer with audited security and an OT DMZ is preferred over a direct connection. The responsibilities of the control network and business applications should be kept separate.
Can the work be done without stopping current production?
Reviewing existing records and some passive observation can usually be done while production continues. If a new measurement point has to be installed or the control network has to be changed, we assess the impact with the plant team and agree on a suitable time.
Do you do PLC programming?
We do not develop PLC application software. Our focus is communication, networking, data integration and OT network security. Any changes needed on the PLC side are coordinated with the plant’s automation team or the machine manufacturer.
Industrial network projects across Türkiye
We deliver industrial network and PLC/OT integration projects at production sites across Türkiye. Passive inventory, site surveys and commissioning are done at the plant during maintenance windows that fit the production schedule. Monitoring and approved configuration changes are handled over secure remote access. Our service areas.
Let's discuss the right architecture for your production network
Let’s plan a technical survey based on your current situation, installed equipment and goals. The first meeting is free of charge; scope and deliverables are set out in a written proposal.